GM6000 Digital Heater Controller Branch: main
SDX-1330
|
This class simulates a "system" whose state is affected by its environment and any number of control systems that may change the environment over time. More...
This class simulates a "system" whose state is affected by its environment and any number of control systems that may change the environment over time.
The design of this class was inspired by the electrical theory surrounding the charging and discharging of a capacitor by a voltage source (potential) through a resistance. The environment in exactly the same way as the various controlling sources, that is as a potential and a series resistance. Although this model is based upon electrical engineering, it is essentially unit-less and may be applied to similarly behaving systems (e.g. thermal systems).
#include <System.h>
Public Member Functions | |
System (double tickPeriodInSeconds, double environmentResistance, double capacitance, double initialOutputPotential) noexcept | |
tickPeriodInSeconds is the time between each call to the tick() operations. | |
void | start (double potential) noexcept |
This operation is used to start an accumulation cycle. | |
void | start (double potential, double resistance) noexcept |
This operation is used to start an accumulation cycle. | |
void | accumulate (double potential, double resistance) noexcept |
This operation is to be invoked zero or more times after one of the start() operations and before the finish() operation. | |
double | finish () noexcept |
This operation is issued after one of the start() operations and zero or more accumulate() operations to calculate the new output potential/state of the system, that is returned as a result. | |
Public Attributes | |
double | _environmentResistance |
This value represents the default value of the resistance between the system and the environmental potential. | |
double | _capacitance |
This value represents the capacity of the system. | |
double | _peq |
This value is used during the start() -> accumulate() -> finish() sequence to hold the accumulated "equivalent" potential of the combined environment and control sources. | |
double | _req |
This value is used during the start() -> accumulate() -> finish() sequence to hold the accumulated "equivalent" resistance of the combined environment and control sources. | |
|
noexcept |
tickPeriodInSeconds is the time between each call to the tick() operations.
controlResistance is the "internal" resistance of the control input to other network. environmentResistance is the "internal" resistance of the environment. capacitance is the amount of charge that can be stored in the system. initialOutputPotential is the initial voltage across the capacitor/system.
|
noexcept |
This operation is to be invoked zero or more times after one of the start() operations and before the finish() operation.
Each invocation accumulates a new potential source into the system calculation. This allows any number of sources, each consisting of a potential and a resistance to affect the next state of the system.
|
noexcept |
This operation is issued after one of the start() operations and zero or more accumulate() operations to calculate the new output potential/state of the system, that is returned as a result.
|
noexcept |
This operation is used to start an accumulation cycle.
It allows several sources to affect the calculation of the system output over the next cycle. In this variant, the potential is that of the "environment" and the resistance is assumed to be that of the environment as specified by the constructor.
|
noexcept |
This operation is used to start an accumulation cycle.
It allows several sources to affect the calculation of the system output over the next cycle. In this variant, the potential is that of the "environment" and the resistance is also that of the "environment" and is used instead of the constant supplied in the constructor.
double Ajax::SimHouse::System::_capacitance |
This value represents the capacity of the system.
E.g. in an electrical system this is the value of the capacitor. It affects the overall "inertia" of the simulated system.
double Ajax::SimHouse::System::_environmentResistance |
This value represents the default value of the resistance between the system and the environmental potential.
double Ajax::SimHouse::System::_peq |
This value is used during the start() -> accumulate() -> finish() sequence to hold the accumulated "equivalent" potential of the combined environment and control sources.
Its value is calculated in the same way as the "open-circuit voltage" in a Thevenin equivalent circuit.
double Ajax::SimHouse::System::_req |
This value is used during the start() -> accumulate() -> finish() sequence to hold the accumulated "equivalent" resistance of the combined environment and control sources.
Its value is calculated in the same way as the "equivalent series resistance" in a Thevenin equivalent circuit.